Product introduction:
The AC/DC Adapter 12V 2A, a key model from the TOPOW TPA289 series, is a 24W power solution engineered for leading OEM clients like Skyworth. With a global 100-240V input and stable 12V/2A output, it delivers robust performance for a wide range of applications, including set-top boxes, network devices, and display terminals. The series is available in multiple regional configurations-including UK, US, Australian, and Brazilian plugs-and is fully certified to international safety and EMC standards. Proven in volume manufacturing, this series reliably supports monthly shipments of over 100,000 units. With an impressive portfolio of 12 international certifications including UL, CB, CE, UKCA, NOM, DOE, FCC, ERP, EAC, GEMS, SAA, and RCM.
Quality Assurance & Testing
100% production testing
Hi-Pot test: 3000VAC/1mA/60s
Full load burn-in: 8 hours minimum
Ripple and noise measurement
Environmental stress screening (ESS)
MTBF verification testing
Automated optical inspection (AOI)

Product Feature
Worldwide Voltage Support
Works with 100-240V AC inputs, ideal for international use.
01
Energy-Saving
Complies with ERP VI efficiency (86.2% average), ≤0.1W no-load power.
02
Robust Protection
Features OCP (≤3.5A), OVP (≤18V), SCP, and passes ±4kV surge tests (IEC61000-4-5).
03
Industrial Durability
100,000-hour MTBF, operates in -10℃~50℃, with vibration/drop/salt-spray resistance.
04
Clean Power Delivery
Tight voltage regulation (11.4V~12.6V), ≤150mV ripple, and fast response (≤30ms rise time).
05
Product application
Networking
Routers, switches
Security
IP cameras, NVRs
Industrial
PLCs, sensors
Consumer Electronics
Printers, LED displays
Certification
With a comprehensive suite of 12 international certifications (including UL, CE, UKCA, SAA), this adapter is your passport to seamless global market access.





Note: With 12+ global certifications, this adapter guarantees safety and performance across regions. The AC DC Adapter 12V 2A is your trusted power solution.
Hot Tags: ac dc adapter 12v 2a, China ac dc adapter 12v 2a manufacturers, suppliers, factory, 10W Adapter, 36w Adapter, AC DC Adapter 12v 2a, ac dc adapter 5v 1a, quick charge 30w, wall mount power adapter
Product specification
1.Input Characteristic
| No. | Item | Unit | Min value | Typical value | Max value | Remarks | ||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | Range of rated input voltage | Vac | 100 | 220 | 240 | |||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | Range of maximum input voltage | Vac | 90 | 264 | ||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | Frequency of rated input voltage | Hz | 47 | 50/60 | 63 | |||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | Current of rated input voltage | A | 0.7 | |||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | Inrush current | A | 60 | cold start@25℃ | ||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | No-Load Input Power Dissipation | W | 0.1 | ERP VI | ||||||||||||||||||||||||||||||||||||||||||||||
2.Output Characteristic
| No. | Item | Unit | Min value | Typical value | Max value | Remarks | ||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | Output voltage | V | 11.4 | 12 | 12.6 | |||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | Rated output current | A | 2.0 | |||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | Ripple & Noise | mV | 150 | Note1 Note2 | ||||||||||||||||||||||||||||||||||||||||||||||
| 2.4 | Average efficiency | % | 86.20 | ERP VI | ||||||||||||||||||||||||||||||||||||||||||||||
| 2.5 | Output load transient response | % | ±5 | |||||||||||||||||||||||||||||||||||||||||||||||
| 2.6 | Output overshoot/ undershoot | % | ±5 | |||||||||||||||||||||||||||||||||||||||||||||||
| 2.7 | Rise time | ms | 30 | Note3 | ||||||||||||||||||||||||||||||||||||||||||||||
| 2.8 | Turn on time | s | 3 | Note2 Note3 | ||||||||||||||||||||||||||||||||||||||||||||||
| 2.9 | Line Regulation | % | ±3 | |||||||||||||||||||||||||||||||||||||||||||||||
| 2.10 | Load Regulation | % | ±5 | |||||||||||||||||||||||||||||||||||||||||||||||
3.Protection Function
| No. | Item | Unit | Yes/No | Minimum value |
Typical value |
Maximum value |
Recover characteristic | |||||||||||||||||||||||||||||||||||||||||||
| 3.1 | Short circuit protection |
A | Yes | Hiccups protected mode ,Don't damage | ||||||||||||||||||||||||||||||||||||||||||||||
| 3.2 | Over current protection |
A | Yes | 2.30 | 3.5 | Hiccups protected mode ,Don't damage | ||||||||||||||||||||||||||||||||||||||||||||
| 3.3 | Over voltage protection |
V | Yes | 18 | ||||||||||||||||||||||||||||||||||||||||||||||
4.Environment Requirement
| No. | Item | Unit | Minimum value | Typical value | Maximum value | ||||||||||||||||||||||||||||||||||
| 4.1 | Operating temperature | ℃ | -10 | 25 | 50 | ||||||||||||||||||||||||||||||||||
| 4.2 | Storage temperature | ℃ | -20 | 25 | 70 | ||||||||||||||||||||||||||||||||||
| 4.3 | Relative humidity | % | 5 | 95 | |||||||||||||||||||||||||||||||||||
| 4.4 | Altitude | M | 5,000 | ||||||||||||||||||||||||||||||||||||
5. Reliability Requirements
| No. | Item | Specification | ||||||||||||||||||||||||||||||||||||||||||
| 5.1 | MTBF | 100000Hours (25℃) | ||||||||||||||||||||||||||||||||||||||||||
| 5.2 | Vibration | 10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth:3.5mm) for 1Hour for each of the perpendicular axes X,Y,Z,there should not be damaged on the appearance,and can work normally. | ||||||||||||||||||||||||||||||||||||||||||
| 5.3 | Drop | 1 corner,3edges,6surfaces each once.Height:100cm,on the wooden board,the plug can be bend,and scratch,but the structure should not be damaged,no noise when sway and can work normally. | ||||||||||||||||||||||||||||||||||||||||||
| 5.4 | Corrosion of gas | Putting the sample in the salt 5% with 24hours,and the electronic test is OK after the test | ||||||||||||||||||||||||||||||||||||||||||
6.Security Test And Safety Certification
| No. | Item | Rating | Standards(or test condition) | |||||||||||||||||||||||||||||||||||||||||||||||
| 6.1 | Hi-pot | 3000Vac | primary to secondary,5mA/60S | |||||||||||||||||||||||||||||||||||||||||||||||
| 6.2 | Insulation Resistance | ≥100M | 500VDC | |||||||||||||||||||||||||||||||||||||||||||||||
| 6.3 | Leakage Current | ≤0.25mA | 240VAC | |||||||||||||||||||||||||||||||||||||||||||||||
| 6.4 | Plug Type | EU/US/BR/UK | ||||||||||||||||||||||||||||||||||||||||||||||||
| 6.5 | Dimensions | 75*49*48mm | ||||||||||||||||||||||||||||||||||||||||||||||||
| 6.6 | Safety Certification | UL/CB/CE/UKCA/NOM/DOE/FCC/ERP/EAC/GEMS/SAA/RCM | ||||||||||||||||||||||||||||||||||||||||||||||||
7.EMC Requirements
| No. | Item | Rating | Standards | |||||||||||||||||||||||||||||||||||||||||||||||
| Power | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 7.1 | conducted interference | CLASS B: | EN55032,FCC part15 | |||||||||||||||||||||||||||||||||||||||||||||||
| 7.2 | radiated interference | CLASS B: | EN55032,FCC part15 | |||||||||||||||||||||||||||||||||||||||||||||||
| 7.3 | SURGE | Differential : ±4 kV common:±4 kV CLASS B: | IEC61000-4-5 | |||||||||||||||||||||||||||||||||||||||||||||||
| 7.4 | EFT | ±0.5kV;Class A, ±1kV;Class B: | IEC61000-4-4 | |||||||||||||||||||||||||||||||||||||||||||||||